3–Fibre Channel Configuration
Setting an FA-PWWN
After refreshing the Brocade
Name as shown in
Setting FA-PWWN with QConvergeConsole CLI
To set the FA-PWWN from the adapter using QConvergeConsole CLI:
1.
In interactive mode of QConvergeConsole CLI, select Main Menu, and then
click Adapter Configuration.
2.
Select HBA Parameters.
3.
Select the appropriate port.
4.
Select Configuration HBA Parameters.
5.
Select Enable Fabric Assign WWN.
6.
On the Enable Fabric Assign WWN Menu, select 1: Enable.
7.
Select the option to Commit Changes.
The following shows an example of setting the FA-PWWN:
HBA Desc.
FW Version
WWPN
WWNN
Link
===============================================================
1: Connection Options
2: Data Rate
3: Frame Size
4: Enable HBA Hard Loop ID
5: Hard Loop ID
6: Loop Reset Delay (seconds)
Figure
Figure 3-18. New FA-PWNN Port Name in GUI
: QLE2742 QLogic 2-port 32Gb Fibre Channel Adapter
: 7.04.00
: 21-00-00-OE-1E-11-4A-38
: 21-00-00-OE-1E-11-4A-38
: Online
switch, the Port Info page shows the Port
®
3-18.
65
BK3254601-00 C