REV A
How to Remove the
Hydraulic Pump
When removing a hose assembly
or fitting, the O-ring on the fitting
and/or hose end must be replaced
and then torqued to specification
during installation. Refer to
Section Two, Hydraulic Hose and
Fitting Torque Specifications.
1 Remove the mounting fasteners from the
hydraulic filter bracket at the function manifold.
Move the filter off to the side.
2 Tag, disconnect and plug the hydraulic hoses
on the pump. Cap the fittings on the pump.
Bodily injury hazard. Spraying
hydraulic oil can penetrate and
burn skin. Loosen hydraulic
connections very slowly to allow
the oil pressure to dissipate
gradually. Do not allow oil to squirt
or spray.
3 Remove the pump mounting bolts. Carefully
remove the pump.