June 2003
REV A
Machine
Drives At Full
Speed With
Platform
Raised
Be sure the circuit
breaker and fuse are
not tripped or blown.
Be sure the batteries
are fully charged and
properly connected.
Part No. 72972
light is
With the key switch
not on
turned to platform
controls and both
Emergency Stop buttons
pulled out to the
ON
position and the platform
in the stowed position,
drive the machine in
either direction. Is the
error indicator light on at
the platform controls?
light
is on
See Chart 13 OR
remove the obstruction
from the pothole guard
OR consult the Genie
Industries Service
Department.
Genie GS-2046 and GS-2646 and GS-3246
Section 5 • Troubleshooting Flow Charts
Check limit switch LS7
good
and LS8 for correct
adjustment.
bad
Adjust LS7 or LS8 (See
Repair Section) OR
repair or replace limit
switch wire circuit.
Chart 14
Check the controller
adjustments (See
Repair Section) OR
replace the platform
controls OR replace the
ECM U5 OR consult the
Genie Industries Service
Department.
5 - 23