Section 4 • Repair Procedures
SCISSOR COMPONENTS
12 Attach a lifting strap from an overhead crane to
the lug on the rod end of the lift cylinder.
13 Remove the pin retaining fasteners from the
cylinder rod-end pivot pin (index #3). Use a soft
metal drift to remove the pin.
Bodily injury hazard. The cylinder
may fall if not properly supported
when the pin is removed.
14 Lower the cylinder onto the number 1 center
pivot pin (index #7).
15 Attach a lifting strap from an overhead crane to
the number 3 inner arm (index #11).
16 Remove the external snap rings from the
number 3 pivot pin (index #4).
17 Use a soft metal drift to remove the number 3
pivot pin (index #4). Remove the number 3
inner arm (index #11) from the machine.
Bodily injury hazard. The number
3 inner arm (index #11) may
become unbalanced and fall if not
properly supported when it is
removed from the machine.
18 Attach a strap from an overhead crane to the
number 2 outer arm (index #15) at the ground
controls side.
19 Use a soft metal drift to remove the number 2
center pivot pin (index #5) at the ground
controls side.
20 Remove the external snap rings from the
number 2 pivot pin (index #16) at the non-steer
end.
4 - 20
Genie GS-2046 and GS-2646 and GS-3246
21 Use a soft metal drift to remove the number 2
pivot pin (index #16) at the non-steer end.
Remove the number 2 outer arm (index #15)
from the ground controls side of the machine.
Bodily injury hazard. The number
2 outer arm (index #15) at the
ground controls side may become
unbalanced and fall if not properly
supported when it is removed from
the machine.
22 Attach a lifting strap from an overhead crane to
the number 2 outer arm (index #15) at the
battery pack side.
23 Remove the external snap rings from the
number 2 center pivot pin (index #5) at the
battery pack side.
24 Use a soft metal drift to remove the number 2
center pivot pin (index #5) at the battery pack
side. Remove the number 2 outer arm (index
#15) from the battery pack side of the machine.
Bodily injury hazard. The number
2 outer arm (index #15) at the
battery pack side may become
unbalanced and fall if not properly
supported when it is removed from
the machine.
25 Attach a lifting strap from an overhead crane to
the number 2 inner arm (index #14).
26 Remove the external snap rings from the
number 2 pivot pin (index #6) from the steer
end of the machine.