Genie GS-2046 Service Manual page 109

Hide thumbs Also See for GS-2046:
Table of Contents

Advertisement

June 2003
REV B
How to Adjust the
System Relief Valve
(after serial number 36044)
Be sure that the hydraulic oil level
is between the
on the oil level indicator decal.
1 Open the hydraulic power unit module tray and
locate the system relief valve on the function
manifold (item BD or CD).
Models without traction control
a
system relief valve
b
function manifold
c
test port
Part No. 72972
and
marks
FULL
ADD
Genie GS-2046 and GS-2646 and GS-3246
Section 4 • Repair Procedures
2 Connect a 0 to 5000 psi / 0 to 350 bar pressure
gauge to the test port on the function manifold
(item BA or CA).
Models with traction control
a
system relief valve
b
function manifold
c
test port
3 Chock both sides of the wheels at the steer end
of the machine.
4 Remove the platform controls from the platform.
Perform this test from the ground
with the platform controls. Do not
stand in the platform.
MANIFOLDS