1st analog special adapter
D 8280
Measured temperature Ch1 Measured temperature Ch1
D 8281
Measured temperature Ch2 Measured temperature Ch2
D 8282
Measured temperature Ch3 Measured temperature Ch3
D 8283
Measured temperature Ch4 Measured temperature Ch4
Number of averaging times
D 8284
for Ch1 (1 to 4095)
Number of averaging times
D 8285
for Ch2 (1 to 4095)
Number of averaging times
D 8286
for Ch3 (1 to 4095)
Number of averaging times
D 8287
for Ch4 (1 to 4095)
D 8288
Error status
D 8289
Model code: K20, K21
2nd analog special adapter
D 8290
Measured temperature Ch1 Measured temperature Ch1
D 8291
Measured temperature Ch2 Measured temperature Ch2
D 8292
Measured temperature Ch3 Measured temperature Ch3
D 8293
Measured temperature Ch4 Measured temperature Ch4
Number of averaging times
D 8294
for Ch1 (1 to 4095)
Number of averaging times
D 8295
for Ch2 (1 to 4095)
Number of averaging times
D 8296
for Ch3 (1 to 4095)
Number of averaging times
D 8297
for Ch4 (1 to 4095)
D 8298
Error status
D 8299
Model code: K20, K21
*1.
Only a 40-point or 60-point type FX
*2.
The model code is "20" for the PT-ADP, and "21" for the PTW-ADP.
Operation and function
-4AD-PT(W)-ADP
FX
3U
Ver.1.00 or later
Ver.1.00 or later
Number of averaging times
for Ch1 (1 to 4095)
Number of averaging times
for Ch2 (1 to 4095)
Number of averaging times
for Ch3 (1 to 4095)
Number of averaging times
for Ch4 (1 to 4095)
Error status
*2
Model code: K10
*1
Number of averaging times
for Ch1 (1 to 4095)
Number of averaging times
for Ch2 (1 to 4095)
Number of averaging times
for Ch3 (1 to 4095)
Number of averaging times
for Ch4 (1 to 4095)
Error status
*2
Model code: K10
3G
37 Operation of Special Devices (M8000 -, D8000 -)
37.2 Supplement of Special Devices (M8000 - and D8000 -)
-4AD-TC-ADP
FX
-4AD-PNK-ADP
3U
Ver.1.00 or later
Measured temperature Ch1
Measured temperature Ch2
Measured temperature Ch3
Measured temperature Ch4
Number of averaging times
for Ch1 (1 to 4095)
Number of averaging times
for Ch2 (1 to 4095)
Number of averaging times
for Ch3 (1 to 4095)
Number of averaging times
for Ch4 (1 to 4095)
Error status
Model code: K11
Measured temperature Ch1
Measured temperature Ch2
Measured temperature Ch3
Measured temperature Ch4
Number of averaging times
for Ch1 (1 to 4095)
Number of averaging times
for Ch2 (1 to 4095)
Number of averaging times
for Ch3 (1 to 4095)
Number of averaging times
for Ch4 (1 to 4095)
Error status
Model code: K11
PLC can be connected.
31
32
33
34
35
36
37
38
A
B
931