Programming Manual - Basic & Applied Instruction Edition
Number and name
Timing Clock (Refer to Section 24.3 for details.) and Positioning [FX
details.)
[M]8330
DUTY (FNC186) instruction: Timing clock output 1
[M]8331
DUTY (FNC186) instruction: Timing clock output 2
[M]8332
DUTY (FNC186) instruction: Timing clock output 3
[M]8333
DUTY (FNC186) instruction: Timing clock output 4
[M]8334
DUTY (FNC186) instruction: Timing clock output 5
[M]8335
Not used
DVIT (FNC151) instruction:
*2
M 8336
Interrupt input specification function enabled
[M]8337
Not used
PLSV (FNC157) instruction:
*2
M 8338
Acceleration/deceleration operation
[M]8339
Not used
[Y000] Pulse output monitor (ON: BUSY/ OFF: READY)
[M]8340
*2
[Y000] Clear signal output function enable
M 8341
*2
[Y000] Zero return direction specification
M 8342
M 8343
[Y000] Forward limit
M 8344
[Y000] Reverse limit
*2
[Y000] DOG signal logic reverse
M 8345
*2
[Y000] Zero point signal logic reverse
M 8346
*2
[Y000] Interrupt signal logic reverse
M 8347
[M]8348
[Y000] Positioning instruction activation
*2
[Y000] Pulse output stop command
M 8349
[Y001] Pulse output monitor (ON: BUSY/ OFF: READY)
[M]8350
*2
[Y001] Clear signal output function enable
M 8351
*2
[Y001] Zero return direction specification
M 8352
M 8353
[Y001] Forward limit
M 8354
[Y001] Reverse limit
*2
[Y001] DOG signal logic reverse
M 8355
*2
[Y001] Zero point signal logic reverse
M 8356
*2
[Y001] Interrupt signal logic reverse
M 8357
[M]8358
[Y001] Positioning instruction activation
*2
[Y001] Pulse output stop command
M 8359
Timing Clock (Refer to Section 24.3 for details.) and Positioning [FX
[Y002] Pulse output monitor (ON: BUSY/ OFF: READY)
[M]8360
*2
[Y002] Clear signal output function enable
M 8361
*2
[Y002] Zero return direction specification
M 8362
M 8363
[Y002] Forward limit
M 8364
[Y002] Reverse limit
*2
[Y002] DOG signal logic reverse
M 8365
*2
[Y002] Zero point signal logic reverse
M 8366
*2
[Y002] Interrupt signal logic reverse
M 8367
[M]8368
[Y002] Positioning instruction activation
*2
[Y002] Pulse output stop command
M 8369
*1.
Available in Ver. 2.20 or later.
*2.
Cleared when PLC switches from RUN to STOP.
*3.
Available in the Ver. 1.30 or later.
886
Operation and function
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
Correspond
FX
FX
FX
-ing special
3G
3U
3UC
, FX
and FX
PLCs] (Refer to Positioning Control Edition for
3G
3U
3UC
*1
*1
*1
*1
*1
*3
*1
and FX
PLCs] (Refer to Positioning Control Edition for details.)
3U
3UC
Applicable model
FX
FX
FX
FX
1S
1N
2N
device
D8330
D8331
D8332
D8333
D8334
D8336
FX
1NC
2NC