13.1
FNC 50 – REF / Refresh
Outline
This instruction immediately outputs the latest input (X) information or the current output (Y) operation result
in the middle of a sequence program.
1. Instruction format
FNC 50
REF
2. Set data
Operand Type
D
n
3. Applicable devices
Bit Devices
Oper-
and
System User
Type
X
Y
1
2
D
n
1: X000, X010 or X020:
2: Y000, Y010 or Y020:
3: FX
/FX
3U
3UC
FX
PLC:
3G
354
Mnemonic
16-bit Instruction
P
REF
5 steps
REFP
Head bit device (X or Y) number to be refreshed
Number of bit devices to be refreshed
(FX
/FX
: multiple of 8 in the range from 8 to 256,
3U
3UC
FX
: multiple of 8 in the range from 8 to 128)
3G
Digit Specification
M T C S D .b KnX KnY KnM KnS T C D R U \G
Up to the final input number (whose least significant digit number is "0")
Up to the final output number (whose least significant digit number is "0")
PLCs:
K8 (H8) or K16 (H10): Up to K256 (H100) (which is a multiple of 8)
K8 (H8) or K16 (H10): Up to K128 (H80) (which is a multiple of 8)
13 High Speed Processing – FNC 50 to FNC 59
Operation Condition
32-bit Instruction
Continuous
Operation
Pulse (Single)
Operation
Description
Word Devices
System
Special
User
Unit
V Z Modify
13.1 FNC 50 – REF / Refresh
Mnemonic
Operation Condition
Data Type
16-bit binary
Others
Real
Charac-
Index
Constant
Number
ter String
K
H
E
3
3
Bit
Pointer
" "
P

Advertisement