14.3

FNC 62 - ABSD / Absolute Drum Sequencer

Outline
This instruction creates many output patterns corresponding to the current value of a counter.
1. Instruction format
FNC 62
D
ABSD
S
S
1
1
S
2
D
n
Oper-
S
S
1
1
S
2
2
n
1: "D .b" is available only in FX
2: This function is supported only in FX
Explanation of function and operation
1. 16-bit operation (ABSD)
In this example, outputs are controlled to ON or OFF by one rotation (0 to 360° using the rotation angle signal
of 1°/pulse).
The current value
(which occupies "n" lines × 2 devices), and consecutive "n" outputs starting from
OFF during one rotation.
Command
input
FNC 62
ABSD
S
X001
2
X001
Rotation angle signal of 1°/pulse
Mnemonic
16-bit Instruction
Head device number storing the data table (with rising and faling point data)
Counter number for monitoring the current value compared with the data table
Head bit device number to be output
Number of lines in the table and the number of output bit devices
[1 ≤ n ≤ 64]
1
and FX
3U
3U
S
D
of the counter is compared with the data table with "n" lines starting from
2
1
S
S
D
1
2
RST
S
2
S
K360
2
14 Handy Instruction - FNC 60 to FNC 69
14.3 FNC 62 - ABSD / Absolute Drum Sequencer
Operation Condition
32-bit Instruction
17 steps DABSD
Operation
Description
Special
Unit
2
PLCs. However, index modifiers (V and Z) are not available.
3UC
/FX
3UC
n
Mnemonic
16- or 32-bit binary
Bit
16-bit binary
Others
" "
are controlled to ON or
D
D
1
11
12
13
14
15
P
16
17
D
S
1
1
18
19
20