Number and name
Pulse width/Pulse period measurement [FX3G PLCs ]
[M]8074
Not used
[M]8075
Pulse width/Pulse period measurement setting flag
[M]8076
[X000] Pulse width/Pulse period measurement flag
[M]8077
[X001] Pulse width/Pulse period measurement flag
[M]8078
[X003] Pulse width/Pulse period measurement flag
[M]8079
[X004] Pulse width/Pulse period measurement flag
M 8080
[X000] Pulse period measurement mode
M 8081
[X001] Pulse period measurement mode
M 8082
[X003] Pulse period measurement mode
M 8083
[X004] Pulse period measurement mode
[M]8084 to [M]8089
Not used
*1.
Available in Ver. 1.10 or later.
Flag
BKCMP (FNC194 to FNC199) instructions - Block
[M]8090
comparison signal
COMRD
M 8091
instructions - Output character quantity selector
signal
[M]8092
[M]8093
[M]8094
[M]8095
Not used
[M]8096
[M]8097
[M]8098
High Speed Ring Counter
High speed ring counter operation (in units of
*3
M 8099
0.1ms, 16 bits)
[M]8100
Not used
*2.
Available in Ver. 2.20 or later.
*3.
For FX
2N
with after M8099 is driven.
For FX
3U
878
Operation and function
(FNC182)
and
BINDA
/FX
, 0.1ms high speed ring counter D8099 will operate after END instruction is executed
2NC
/FX
, 0.1ms high speed ring counter D8099 will operate after M8099 is driven.
3UC
37 Operation of Special Devices (M8000 -, D8000 -)
37.1 Special Device List (M8000 -, D8000 -)
FX
FX
FX
3G
3U
3UC
*1
*1
*1
*1
*1
*1
*1
*1
*1
*2
(FNC261)
*2
Applicable model
Correspond
-ing special
FX
FX
FX
1S
1N
2N
device
D8074
to
D8079
D8080
to
D8085
D8086
to
D8091
D8092
to
D8097
D8074
to
D8079
D8080
to
D8085
D8086
to
D8091
D8092
to
D8097
D8099
FX
FX
1NC
2NC