Mitsubishi Electric MELSEC FX3U Programming Manual page 844

Melsec fx series programmable logic controllers
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
3. Example of parallel branch
Do not use MPS, MRD, MPP, ANB and ORB instructions in a program with branches and recombination.
Even in a load driving circuit, MPS instructions cannot be used immediately after STL instructions.
In the same way as programs for general state relays, program the drive processing first, and then program
the transfer processing.
Continuously program all transfer processing.
<SFC program>
20
X000
1
21
4. Example of parallel recombination
Do not use MPS, MRD, MPP, ANB and ORB instructions in a program with branches and recombination.
Even in a load driving circuit, MPS instructions cannot be used immediately after STL instructions.
Pay attention to the programming order so that a branch line does not cross a recombination line.
<SFC program>
29
X010
9
50
<Step ladder>
X010
X011 X012
Before recombination, first program the drive processing of state relays.
After that, program only the transfer processing to recombination state relays.
842
<Step ladder>
Y000
TRAN
31
41
39
Y010
X011 X012
TRAN
STL
S29
Y010
STL
S39
Drive
Y011
processing
STL
S49
Y012
STL
S29
STL
S39
Transfer
processing
STL
S49
SET
S50
STL
S20
Y001
X000
SET
S21
SET
S31
SET
S41
49
Y011
<List program>
STL
S29
OUT
Y010
STL
S39
OUT
Y011
STL
S49
OUT
Y012
STL
S29
STL
S39
STL
S49
LD
X010
AND
X011
AND
X012
SET
S50
35 SFC Program and Step Ladder
35.2 Step Ladder
<List program>
STL
OUT
Drive
LD
processing
SET
SET
SET
Transfer
processing
Y012
S20
Y000
X000
S21
S31
S41