Errors
An operation error is caused in the following cases; The error flag M8067 turns ON, and the error code is
stored in D8067.
• When "n" ("2n" in 32-bit operation) devices starting from
corresponding device range (error code: K6706)
• When "n" ("2n" in 32-bit operation) devices starting from
devices starting from
• When "n" ("2n" in 32-bit operation) devices starting from
devices starting from
Program example
In the program shown below, the constant "8765" is subtracted from the data stored in D100 to D102 when
X010 is set to ON, and the operation result is stored in D200 and later.
X010
b15
D100
K12345
D101
K8701
D102
K3502
636
(error code: K6706)
D
(error code: K6706)
D
FNC193
D100
K8765
BK-P
b0
b15
b0
K8765
25 Block Data Operation – FNC190 to FNC199
25.2 NFC193 – BK– / Block Data Subtraction
,
S
S
1
2
overlap "n" ("2n" in 32-bit operation)
S
1
overlap "n" ("2n" in 32-bit operation)
S
2
D200
K3
END
b15
b0
D200
K3580
D201
K-64
D202
K-5263