Mitsubishi Electric MELSEC FX3U Programming Manual page 87

Melsec fx series programmable logic controllers
Table of Contents

Advertisement

FX
/FX
/FX
Series Programmable Controllers
3G
3U
3UC
Programming Manual - Basic & Applied Instruction Edition
Device name
Counter
General type up counter
(16 bits) [variable]
Latched (battery backed)
type up counter
(16 bits) [variable]
General type
bi-directional counter
(32 bits) [variable]
Latched (battery backed)
type
bi-directional counter
(32 bits) [variable]
High speed counter
1-phase 1-counting input
Bi-directional (32 bits)
1-phase 2-counting input
Bi-directional (32 bits)
2-phase 2-counting input
Bi-directional (32 bits)
Data register (32 bits when used in pair form)
General type (16 bits)
[variable]
latched (battery backed)
type (16 bits)
[variable]
latched (battery backed)
type (16 bits)
[fixed] <file register>
Special type (16 bits)
Index type (16 bits)
Extension register/Extension file register
Extension register
(16 bits)
Extension file register
(16 bits)
Pointer
For jump and branch call
Input interrupt
Input delay interrupt
Timer interrupt
Counter interrupt
Nesting
For master control
C0 to C99
100 points
C100 to C199
100 points
C200 to C219
20 points
C220 to C234
15 points
8 points maximum can be used among C235 to C255
C235 to C245
[latched (battery backed) type].
The setting can be changed between the latched (battery
backed) type and the non-latch type using parameters.
−2,147,483,648 to 2,147,483,647 counts
C246 to C250
Hardware counter
1 phase: 100 kHz × 6 points, 10 kHz × 2 points
2 phases: 50 kHz (1 edge count),
50 kHz (4 edge count)
Software counter
C251 to C255
1 phase: 40 kHz
2 phases: 40 kHz (1 edge count),
10 kHz (4 edge count)
D0 to D199
200 points
D200 to D511
312 points
D512 to D7999
7488 points
<D1000 to
<7000
D7999>
points>
*2
D8000 to D8511
512 points
V0 to V7, Z0 to Z7 16 points
32768
R0 to R32767
points
32768
ER0 to ER32767
points
P0 to P4095
4096 points For CJ and CALL instructions
I0
to I5
6 points
I6
to I8
3 points
I010 to I060
6 points
N0 to N7
8 points
Description
Counts 0 to 32,767
The setting can be changed between the
latched (battery backed) type and the non-
latched type using parameters.
−2,147,483,648 to
+2,147,483,647 counts
The setting can be changed between the
latched (battery backed) type and the non-
latched type using parameters.
*3
The setting can be changed between the
latched (battery backed) type and the non-
latched type using parameters.
Among the 7488 fixed latched (battery
backed) type data registers, D1000 and later
can be set as file registers in units of 500
points.
latched (battery backed)
Available only while a memory cassette is
mounted
For HSCS instruction
For MC instruction
4 Devices in Detail
4.1 Device Number List
Reference
Section 4.6
Section 4.7
Section 4.9
Chapter 37
Section 4.11
Section 4.10
Section 4.12
10
85
1
2
3
4
5
6
7
8
9

Advertisement

Table of Contents
loading

This manual is also suitable for:

Melsec fx3ucMelsec fx3g

Table of Contents