Maximum switching current (AC)
Maximum switching current (DC)
Maximum switching voltage (AC)
Maximum switching voltage (DC)
Maximum power factor
Table 3-34
Electrical requirements for sensors and relays
3.6.4.2
HiPath 1150/1190/1190R
On the HiPath 1150/1190/1190R the external audio source (e.g., music) is connected directly
to the MB at the X8 slot (see Figure 3-4) or to an analog extension port.
3.6.4.3
Connection Values for an External Music Source*
Internal
Resistance
Maximum Input
Voltage
***〉
This port supports commercial CD players, receivers, MD, etc. (See Figure 4-39, "Protection and Grounding Connection
Diagram", on page 4-54).
3.7
Power Supply Unit (PSU)
Introduction
The power supply unit (PSU) provides the required voltages for the proper operation of the
entire system.
The power supply may or may not have inputs for connecting batteries.
A31003-K1160-S100-03-7620
Service Manual
Sensor
Relay
30 V
1.25 A
2.00 A
RMS
24 V
0,95
2.4kΩ
-10 dBm
Modules
Power Supply Unit (PSU)
3-54