Table 2-5 Technical Data - Siemens HiPath 1100 Service Manual

Phone systems
Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

Element
Rated Voltage
(Output)
Call Voltage
Dialing Modes for Calls to other Public or Private Exchanges:
MF Transmission Level:
Low Group
*
High Group
*
Pre-Emphasis
Pulse Duration
**
Interdigit Pause
**
DP (Dial Pulse):
Pulse/Pause
Ratio
**
Interdigit Pause
**
Open loop
isolation
resistance
between a/b or a/
ground or b/
ground
Closed loop line
resistance/
continuous loop
current
Incoming Call
Detection
*〉
Values vary according to the country. The values shown are specifically for Brazil.
**〉
Values depend on the country settings, which are configurable. The values shown are default values for Brazil.
Table 2-5
Technical Data
A31003-K1160-S100-03-7620
Service Manual
HiPath 1120
U1: 8 Vrms
U2: 23 Vrms
U3:
40 V
/60Hz
rms
65 V
/20Hz (CND)
rms
65 V
/25Hz (SPA)
rms
42 V
/25Hz (RSA)
rms
2:1 (approximately 70:30ms = 10 Hz)
Complies with national requirements/standards
HiPath 1150
5.1 VDC; .
26.4 VDC; .
50 V
+ 97 V
AC
DC
42 V
+ 85.8 V
AC
DC
(RSA)
-11 dBm
-9 dBm
2 dB
90ms min.
90ms min.
800ms
> 10MΩ
> 9V
RMS
System Data
Technical Data
HiPath 1190
/ 0.13A - 25Hz
/ 0.13A - 25Hz
2-9

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 1150Hipath 1120Hipath 1190