Siemens HiPath 1100 Service Manual page 43

Phone systems
Hide thumbs Also See for HiPath 1100:
Table of Contents

Advertisement

3.4
Motherboard (MB)
Introduction
The MB is the main board for the HiPath 1100 system. The MB provides all functions required
for PABX operation.
Functions
CLIP - external calling number identification (service must be provided by local carrier)
Central Processing Unit (CPU)
DTMF generator and detector
Conference circuits
Tone generators
Music source
Memory (software + client's data base)
Digital switch
Signaling
Fax/DID.
Warning
!
FAILURE TO REPLACE BATTERY WITH SPECIFIED BATTERY TYPE CAN CAUSE
RISK OF EXPLOSION. DISCARD USED BATTERIES ACCORDING TO INSTRUC-
TIONS.
3.4.1
HiPath 1120
Outputs/Inputs
8 interfaces for standard telephones with 4 for system telephones
2 external analog lines
Mini DIN-6 connector for V.24 adapter
Mini DIN-4 connector for USB adapter
Power supply
Baby Board VCC Module;
A31003-K1160-S100-03-7620
Service Manual
Modules
Motherboard (MB)
3-8

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Hipath 1150Hipath 1120Hipath 1190

Table of Contents