Modules
Expansion Modules (EB)
3.5.4
TME1 Module
A TME1 module can be configured for operating as a E1 CAS or S2 access.
I
Warning
!
The TME1 module will be shipped from the factory already configured for operating
as a CAS interface.
In order to enable the module to operate as a S2 interface it must be reconfigured
by followinf a specified procedure in the S2M Maintenance.
E1 CAS Access
●
A TME1 module with E1 CAS access consists of a Digital Interface Unit (DIU) used for
connecting the HiPath 1150/1190/1190R to the PSTN via a E1 trunk. The E1 trunk can carry
30 digital voice channels. However, the HiPath 1150 systems use up to 20 channels, while the
HiPath 1190 systems use up to 30 channels with the TME1 module allocated to slot 1 and up
to 15 channels when it is allocated to slot 11.
Functions
●
Increases the system's number of external lines
●
Provides Caller ID (CLIP) and Direct Dialing to Extensions (DID) to help reduce
●
call loss rate while simplifying access for the user.
HiPath 1190/1190R: In the event of a problem occurring with the Master TME1 link
with E1 CAS access (see "TME1 module display readings (CAS Access)" on page
3-40) during an external call, the system will go into a mute state for 3 seconds while
the system clock is synchronized.
3-33
A31003-K1160-S100-03-7620