Yw = Value - Omron MX2 Series User Manual

Hide thumbs Also See for MX2 Series:
Table of Contents

Advertisement

Drive Programming
Command
Instruction to access digital outputs by
word.
Each bit reflects one of the outputs.
Yw = <value>
Note: The inputs have to be assigned to digital multifunction input (by the multifunction 44 to 49 for
MX2 and RX, 35 to 41 for LX).
Yw = 1
bit 0
Yw = 2
bit 1
Yw = 4
bit 2
Yw = 8
bit 3 (only if expanded I/O board used)
Yw = 16
bit 4 (only if expanded I/O board used)
Yw = 32
bit 5 (only if expanded I/O board used, and enough outputs)
Yw = 64
bit 6 (only if expanded I/O board for LX is used)
Example
Flowchart
This example acquires the state of the X(02)-X(05) input terminals and outputs it to Y(00)-Y(03) output
terminals.
To cut X(00) – X(01), the U(00) value is divided by 4. To cut X(06) – X(07), the U(00) value is masked
by 15.

Yw = value

Description
Format
Arguments
• Value: any variable or constant
Text
60

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lx seriesRx series

Table of Contents