Drive Programming

5-5 Digital input Functions

These variables correspond to the settings available for the digital multifunction input terminals.
Setting the variable to 1 will simulate the function as if the terminal was closed in a digital input. It is
interesting to note that the multifunction does not need to be configured in order to use the function.
E.g. FW := 1 will generate a RUN Forward command (as used in some examples).
Please refer to the inverter user manual for details about the individual functions.
Values: · 0: Off
· 1: On
Function
Description
FW
Forward
RV
Reverse
CF1-CF4
Multi-speed 1-4
JG
Jogging
DB
External Brake
SET
Second control
nd
2CH
2
acceleration/deceleration time
FRS
Free run
EXT
External trip
USP
Unattended start protection
CS
Change from commercial power
SFT
Software lock
AT
Change of analog input
rd
SET3
3
control
RS
System reset
STA
Start of 3 wires
STP
Stop of 3 wires
F/R
Forward/Reverse of 3 wires
PID
Switch PID
PIDC
Reset of PID integration
CAS
Control gain switching
UP
Increasing speed from remote
DWN
Decreasing speed from remote
UDC
Clear data from remote operation
OPE
Change to operator
SF1-SF7
Multi-speed bit 1-7
OLR
Overload protection switch
TL
Torque Limit Enable
TRQ1-2
Torque Limit Selection 1-2
PPI
P/PI switching
BOK
Brake Confirmation
ORT
Orientation
LAC
LAD Cancel
PCLR
Clear Position Deviation
Pulse train position command input
STAT
permission
ADD
Add Setting Frequency
F-TM
Forced Terminal Block
ATR
Torque reference input permission
KHC
Integrated power clear
SON
Servo ON
FOC
Preliminary excitation
X(00) –
Drive Programming (MI1-MI8)
X(07)
AHD
Analog command on hold
CP1-3
Position command selection 1-3
ORL
Origin return limit signal
ORG
Origin return start signal
MX2
RX
LX
Usage
x
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
R/W
x
R/W
R/W
R/W
x
R/W
x
R/W
R/W
x
R/W
x
x
R/W
R/W
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
x
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
x
x
R/W
x
R/W
x
x
R/W
x
R/W
x
R/W
x
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
x
x
R/W
x
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
x
R/W
32
Comment
C001-C009 = 00
C001-C009 = 01
C001-C009 = 02-
05
C001-C009 = 06
C001-C009 = 07
C001-C009 = 08
C001-C009 = 09
C001-C009 = 11
C001-C009 = 12
C001-C009 = 13
C001-C009 = 14
C001-C009 = 15
C001-C009 = 16
C001-C009 = 17
C001-C009 = 18
C001-C009 = 20
C001-C009 = 21
C001-C009 = 22
C001-C009 = 23
C001-C009 = 24
C001-C009 = 26
C001-C009 = 27
C001-C009 = 28
C001-C009 = 29
C001-C009 = 31
C001-C009 = 32-
38
C001-C009 = 39
C001-C009 = 40
C001-C009 = 41-
42
C001-C009 = 43
C001-C009 = 44
C001-C009 = 45
C001-C009 = 46
C001-C009 = 47
C001-C009 = 48
C001-C009 = 50
C001-C009 = 51
C001-C009 = 52
C001-C009 = 53
C001-C009 = 54
C001-C009 = 55
C001-C009 = 56-
63
C001-C009 = 65
C001-C009 = 66-
68
C001-C009 = 69
C001-C009 = 70

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Lx seriesRx series

Table of Contents