2- Specifications

The table below lists the programming-related specifications of the Drive Programming function.
Item
Programming language
Input device
Max. program size
Programming
support
function
(programming
software)
Execution format
External input
External Output
Instructions
Number of variables
Specification
Flow Chart and Text language
Windows personal computer (OS: Windows XP-SP3, Windows Vista, Windows 7)
1024steps (The internal storage capacity of the inverter is 1024 steps or 6 Kilobytes.)
-Editing (on Windows) / - Display (on Windows)
-Program syntax check (on Windows)
-Downloading, uploading, and full clearance of program
Execution by interpreter in an execution cycle of 2ms per instruction (possible subroutine call with
nesting in up to 8 layers)
Contact
Signal
Program run signal input
Multifunction terminals
General-purpose analog input
General-purpose output terminal
General-purpose analog output
(1) Program control instructions
-Loop (For) / - Unconditional branching (Goto) / -Time control (Wait)
-Conditional branching (If Then, Ifs Then Else, Select Case, Until, and While)
-Subroutine (call, sub) / - Others (Entry, End, Sub, End Sub, Inc, and Dec)
(2) Arithmetic instructions
-Arithmetic operation (+,-,*,/) / - Remainder (Mod) / -Substitution (=)
-Absolute value (Abs) / - Logic operation (Or, And, Xor, and Not)
(3) Input/Output control
-General-purpose input/output (bit input, word input, bit output, and word output)
- Reading of inverter input terminal.
(4) Timer control: - Delay operation / -Timer control
(5) Parameter control: - Rewriting of parameters by reselecting code on the operator's display
User-defined variable
Internal user variable
Set frequency
Acceleration time
Deceleration time
Monitoring variable
Bit commands
Output Functions
General-purpose
input
contact
Extended IO option input
contact
General-purpose
output
contact
Extended output contact
Internal user contact
Internal timer contact
Internal timer counter
Inverter input/output
User Monitor
User trip
24v open – collector input (using intelligent input terminals)
RX: Assign to the PRG terminal / Always run
MX2: Assign to the PRG terminal / Always run
RX: Up to 8 terminals (X(00) to X(07))
MX2: Up to 8 terminals (X(00) to X(07))
XA(0): 0 to 10V (O terminal)
XA(1): 4 to 20mA (OI terminal)
XA(2): 0 to 10V (O2 terminal) (Only RX)
RX: Up to 6 terminals (Y(00) to Y(05))
MX2: Up to 3 terminals (Y(00) to Y(02))
YA (0): Assignable to the EO terminal (FM terminal for RX)
YA (1): Assignable to the AM terminal
YA (2): Assignable to the AMI terminal (Only RX)
U (00) to U (31) (32 variables)
UL (00) to UL (07) (8 variables)
SET-Freq
ACCEL
DECEL
FM, Iout, Dir, PID-FB, F-CNV, Tmon, Vout, Power, RUN-Time, ON-
Time, PlsCnt (Only
RX),
POS, STATUS, DCV, ERR CNT, ERR(1),
ERR(2), ERR(3), ERR(4), ERR(5), and ERR(6)
FW, RV, CF1, CF2,CF3,CF4,JG,DB,SET,TCH,FRS,EXT,USP,CS,SFT,
AT, RS, STA, STP, F/R, PID, PIDC, UP, DWN, UDC, OPE, SF1, SF2,
SF3, SF4, SF5, SF6, SF7, OLR, TL, TRQ1-2, BOK, LAC, PCLR, ADD,
F-TM, ATR, KHC, AHD, CP1-3, ORL, ORG, SPD, RS485, HLD, ROK,
DISP.
RUN, FA1, FA2, OL, OD, AL, FA3, OTQ, UV, TRQ, RNT, ONT, THM,
BRK, BER, ZS, DSE, POK, FA4, FA5, OL2, ODc, OIDc, FBV, NDc,
LOG1, LOG2, LOG3, WAC, WAF, FR, OHF, LOC, IRDY, FWR, RVR,
MJA, WCO, WCOI, FREF, REF, SETM, EDM.
LX : X(00) to X(06) (7 contacts)
RX : X (00) to X (07) (8 contacts)
MX2 : X(00) to X(07) (8 contacts)
LX : X(07) to X(11) (3G3AX-EIO-E expansion card)
RX : -----
MX2 : -----
LX : Y(00) to Y(03) (4 contacts)
RX :Y(00) to Y(05) (6 contacts)
MX2 : Y(00) to Y(02) (3 contacts)
LX: Y(04) to Y(06) (3G3AX-EIO-E expansion card)
MX2 & RX : -----
UB (00) to UB (7) (8 contacts)
TD (0) to TD (7) (8 counter contacts)
TC (0) to TC (7) (8 counters)
Specification by code on the remote operator's display
UMon(00) to UMon(02) (3 user monitors)
Makes the inverter trip (10 trips)