6-4 Timer Control Commands

Command
This instruction sets the count of the timer
in <value 2> and starts the timer counter.
When the timer output "TD (K)" is turned
on/off, <value 1> is turned on/off. It is
important to note, that meantime counting
proceeds, the <value 1> remains
unchanged from original value.
Delay on/off <value 1>TD(k)<value 2>
Timing chart
Example
Sample program that activates/deactivates the FW instruction with Delay On/Delay Off instruction.

Delay

Description
Format
Flowchart
Arguments
• Value 1: any variable.
• Value 2: any variable or constant
(time in 10 x ms)
• K: number of timer.