D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 9.0 Off-Board Points
.
9.4.3

Installation

For the most effective installation, use the
following four-step process:
1. Set the OctoPOPIT switches. Refer to Section

9.4.4 Setting the OctoPOPIT Switches.

2. Physically mount the OctoPOPIT in the
enclosure. Refer to Section 9.4.5 Mounting
OctoPOPITs, page 53.
3. Wire the OctoPOPIT. Refer to Section 9.4.6
Wiring OctoPOPITs on page 53.
4. Wire the OctoPOPIT sensor loops. Refer to
Section OctoPOPIT Sensor Loops on page 57.
9.4.4
Setting the OctoPOPIT Switches
The D8128D OctoPOPIT has two sets of DIP
switches (Figure 17 on page 51). Use the DIP
switches on the top of the unit (with the terminal
strip along the left edge) to set the address for
the OctoPOPIT. Use the DIP switches at the
bottom of the unit to enable or disable individual
points connected to the OctoPOPIT.
Address Switches
The switches on the D8128D OctoPOPIT set
point assignments and line termination. These
switches are easier to set before mounting the
D8128D in the enclosure.
Switches 1, 2, 3, and 4 assign the OctoPOPIT
sensor loops to point numbers on the control
panel. Table 14 shows the OctoPOPIT switch
settings for point assignments.
Switch 5 sets line termination. Refer to Table 15:
Switch 5 Settings for Line Termination.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09
Table 14:
D8128D OctoPOPIT Switch Settings
ZONEX 1
D8128D Address Switches
Points 9 to
127
1
2
9 to 16
ON
ON
17 to 24
ON
ON
25 to 32
ON
ON
33 to 40
ON
ON
41 to 48
ON
OFF
49 to 56
ON
OFF
57 to 64
ON
OFF
65 to 72
ON
OFF
73 to 80
OFF
ON
81 to 88
OFF
ON
89 to 96
OFF
ON
97 to 104
OFF
ON
105 to 112
OFF
OFF
113 to 120
OFF
OFF
121 to 127
OFF
OFF
* Line Termination Switch
For the D8128D OctoPOPITs assigned to
Points 121 to 127, 241, and 247, set Point
Input Switch 8 to the OPEN position.
D9412GV4 uses Points 9 to 127 on Zonex
1 and Points 129 to 247 on Zonex 2.
D7412GV4 uses Points 9 to 75 on Zonex 1
only.
Table 15: Switch 5 Settings for Line
Termination
Is a D8125 POPEX
Module connected?
No
Yes
Point DIP Switches
Each point connected to the D8128D is enabled
by closing the respective DIP switch, or disabled
by opening the DIP switch. For example, to
disable a device connected to the P3 Terminal
(Point 3), move DIP switch number 3 to the
OPEN position.
Use the point DIP switches to disable conflicting
points, such as when a D9210C Access Control
Module must be assigned to a point that falls
within the range of the D8128D OctoPOPIT. In
this example, a D9210C is assigned to Point 20.
On the same system, a D8128D OctoPOPIT is
ZONEX 2
Points 129
3
4
5
to 247
ON
ON
*
129 to 136
ON
OFF
*
137 to 144
OFF
ON
*
145 to 152
OFF
OFF
*
153 to 160
ON
ON
*
161 to 168
ON
OFF
*
169 to 176
OFF
ON
*
177 to 184
OFF
OFF
*
185 to 192
ON
ON
*
193 to 200
ON
OFF
*
201 to 208
OFF
ON
*
209 to 216
OFF
OFF
*
217 to 224
ON
ON
*
225 to 232
ON
OFF
*
233 to 240
OFF
ON
*
241 to 247
Switch 5 Setting(s) on
D8128D OctoPOPIT(s)
Set Switch 5 of only one
D8128D to ON
Set Switch 5 of all
D8128Ds to OFF
52