D9412GV4/D7412GV4 v2.03 | Installation and System Reference Guide | 12.0 SDI Devices
.
Table 24: Address Switch Settings for
Access Control Module
Door
Combined Rotary
Controller
Switch Settings
Default
1
2*
3
4
5
6
7
8
1
2*
3
4
5
6
7
8
*D7412GV4 supports doors 1 & 2

12.4 SDI Addresses 88 and 92

SDI Addresses 88 and 92 are available with
D9412GV4/D7412GV4 v2.03 Control Panels
and are used for several different applications.
Only one device can be assigned to SDI
Address 88 at a time. Likewise, only one device
can be assigned to SDI Address 92 at a time.
When the Reset Pin (labeled S1) is closed, all
SDI communication module addresses are
automatically enabled for RPS communication
without restriction. Refer to Figure 4: Reset Pin
on page 22 to locate the reset pin.
Bosch Security Systems, Inc. | 7/16 | F01U265457-09
Fail Safe
Response
0
-
81
Unlock
82
Unlock
83
Unlock
84
Unlock
85
Unlock
86
Unlock
87
Unlock
88
Unlock
91
Lock
92
Lock
93
Lock
94
Lock
95
Lock
96
Lock
97
Lock
98
Lock

12.4.1 Local RPS Programming

Use the DX4010i or the DX4010V2 serial
communication module at SDI Address 88 or
SDI Address 92 to locally connect with RPS in
Enhanced Direct mode. This connection
method also allows diagnostic and history
retrieval.
When a serial communication modules
is installed at an SDI Address, it cannot
be used for central station
communications.
UL requires that serial communication
modules be used for programming
only.

12.5 SDI Network Interface Modules

D9412GV4/D7412GV4 v2.03 Series Control
Panels support up to four network interface
modules that provide connection for two-way
communication over Ethernet networks. Up to
two Bosch Security Systems, Inc. B426/B420
Ethernet Communication Modules can be
installed on the SDI2 bus. Refer to 13.7
B420 Ethernet Communication Module
or for details regarding the SDI2 network
interface modules. Likewise, up to two Bosch
Security Systems, Inc. DX4020 Network
Interface Modules can be installed on the SDI
bus
For programming information on enhanced
communications, refer to the Control Panels
(D9412GV4/D7412GV4 v2.03) Program Entry
Guide (P/N: F01U265459).
The B426/B420 modules can be installed on
the SDI bus when configured to emulate
DX4020 modules. Regardless of bus type, the
modules can be up to 1000 ft (305 m) from the
control panel or auxiliary power supply using
22 AWG (0.8 mm) wire.
The DX4020 can be installed on the SDI bus up
to 1000 ft (305 m) from the control panel or
auxiliary power supply using 22 AWG (0.8 mm)
wire.
The ITS-DX4020-G GPRS/GSM IP
Communicator enables two-way IP or dialed
communication over a commercial GPRS/GSM
network. Typical applications are event
reporting to a central monitoring station and
remote access to Bosch intrusion control
panels.