Connecting The Router To Power; Connecting The Acx1000 Or Acx1100 Router To Earth Ground - Juniper acx1000 User Manual

Universal access router
Hide thumbs Also See for acx1000:
Table of Contents

Advertisement

CHAPTER 12

Connecting the Router to Power

Connecting the ACX1000 or ACX1100 Router to Earth Ground

Copyright © 2017, Juniper Networks, Inc.
Connecting the ACX1000 or ACX1100 Router to Earth Ground on page 103
Connecting DC Power Cables to the ACX1000 or ACX1100 Router on page 105
Connecting AC Power Cords to the ACX1100 Router on page 107
To ground the DC-powered router, you need the following tools:
Phillips (+) screwdriver, number 2
ESD grounding wrist strap
Two SAE 10-32 screws and flat washers (not provided)
Grounding lug, Panduit LCD6-14BH-L or equivalent (not provided)
Grounding cable, minimum 14 AWG (2 mm
You ground the router by connecting a grounding cable to earth ground and then attaching
it to the chassis grounding points. To ground the router:
Verify that a licensed electrician has attached the cable lug provided with the router
1.
to the grounding cable.
Attach an electrostatic discharge (ESD) grounding strap to your bare wrist, and connect
2.
the strap to an approved site ESD grounding point. See the instructions for your site.
Ensure that all grounding surfaces are clean and brought to a bright finish before
3.
grounding connections are made.
Connect the grounding cable to a proper earth ground.
4.
Detach the ESD grounding strap from the site ESD grounding point.
5.
Attach an ESD grounding strap to your bare wrist and connect the strap to one of the
6.
ESD points on the chassis.
2
) 90° C wire (not provided)
103

Advertisement

Table of Contents
loading

This manual is also suitable for:

Acx1100

Table of Contents