ACX1000 and ACX1100 Universal Access Router
Table 24: Alarm Contact Connector Pinouts (continued)
Pin
Number
Signal Definition
3
ALARM_IN2_NO/NC
4
ALARM_IN3_NO/NC
5
ALARM_OUT3_REF
6
ALARM_IN0_REF
7
ALARM_IN1_NO/NC
8
ALARM_IN2_IN3_REF
9
ALARM_OUT2_REF
10
ALARM_OUT3_NO/NC
11
ALARM_OUT0_NO/NC
12
ALARM_OUT0_REF
13
ALARM_OUT1_NO/NC
14
ALARM_OUT1_REF
15
ALARM_OUT2_NO/NC
Related
Documentation
64
Direction
CLI Port Mapping
Input
Input Alarm Port 2
Input
Input Alarm Port 3
Output
Reserved for Minor
alarm
Input
Input Alarm Port 0
Input
Input Alarm Port 1
Input
Input Alarm Port 2 and
Input Alarm Port 3
Output
Reserved for Major
alarm
Output
Reserved for Minor
alarm
Output
Output Alarm Port 0
Output
Output Alarm Port 0
Output
Output Alarm Port 1
Output
Output Alarm Port 1
Output
Reserved for Major
alarm
ACX1000 and ACX1100 Universal Access Router Overview on page 3
Front Panel of an ACX1000 Router on page 30
LEDs on ACX1000 and ACX1100 Routers on page 35
Alarm Contact Port on ACX1000 and ACX1100 Routers on page 27
Function
External alarm input 2 (if voltage on this pin is
between 24V to 72V with reference to Pin 8,
alarm input 2 is in closed condition)
External alarm input 3 (if voltage on this pin is
between 24V to 72V with reference to Pin 8,
alarm input 3 is in closed condition)
External alarm output 3 (this pin is connected
to Pin 10 in closed condition)
External alarm input 0 (Reference for Pin 1)
External alarm input 1 (if voltage on this pin is
between 24V to 72V with reference to Pin 2,
alarm input 1 is closed)
Common contact for external alarm input 3 and
4 (Reference for Pin 3 and Pin 4)
External alarm output 2 (this pin is connected
to Pin 15 in closed condition)
External alarm output 3 (this pin is connected
to Pin 5 in closed condition)
External alarm output 0 (this pin is connected
to Pin 12 in closed condition)
External alarm output 0 (this pin is connected
to Pin 11 in closed condition)
External alarm output 1 (this pin is connected
to Pin 14 in closed condition)
External alarm output 1 (this pin is connected
to Pin 13 in closed condition)
External alarm output 2 (this pin is connected
to Pin 9 in closed condition)