4.2 Disassemble/Assemble of Each Unit
4.2.1 Keyboard
(1) Normal (normal size)
Step 1.
Remove key top using key top puller.
Step 2.
Remove key switch.
(2) SHIFT key (includes the same size keys)
REV.-A
Step 1 .
Remove key top of CTRL and A which is located on the top of specified key top.
Step 2.
Insert a thin minus screw driver between key tops and lift up one end of corre-
sponding key. Lock can be removed.
Step 3.
Shift key and remove it from support bar.
(3) SPACE key
Step 1.
Remove key tops Z, X, C, V, B, N, ..... which are located on the top of SPACE bar.
Step 2.
Insert a thin minus screw driver between key tops and lift up one end of key. Lock
can be removed.
Step 3.
Remove key from support bar using a little screw driver.
(4) SHIFT key
Step 4.
Remove SHIFT key from switch cover using key top puller.
- Fig.
4-16
Fig.
4-17
Fig.
4-18
4-8