Press [ENT], and set the PC to be ready to receive.

12.3.3 Communication setup

The communication parameter is set when stored
data is received or sent between the instrument and
the PC etc.

12.3.3.1 Receiving data setting

Select the 4. COMMUNICATION SETUP and press
[ENT] to view the COMM. SETTING
SELECTION.
[1. RECEIVE RECT. DATA]
Select the 1. RECEIVE RECT. DATA and press
[ENT] to view the following screen.
Press [ENT] to open the selection window. Select
each setting and press [ENT].
Press [ACCEPT] when all selections are made.
• DISP.# AXIS: BASIS DIRECT., RIGHT ANGLE, or HEIGHT is selected when data
is transferred between the TS and PC. (cfr. "13.2 Coordinate axis definition")
They are used for matching coordinate system between definition in the instrument and
definition in the external device when they are different. However, it is necessary to match
122