EDM settings can be selected by pressing [F1]
[EDM].
For example, change 1.PRIM. MEAS KEY (MEAS)
to TRACK SHOT or TRACK CONT if you want to
use tracking measurement with primary MEAS key
(MEAS).
The target type can be selected by pressing [F2] [TARGET].

4.9 Offset

Press the [F2] [OFFSET] to view the OFFSET
screen.
Offset enables you to work with Offset. The
following Offsets are available.
Press [ENT] to view the offset input window. Input
the RO offset value by pressing each keys.
DO values are input in the same manner.
Press [ENT] and then [ACCEPT] to view the MEASURE screen.
The S.dst (slope distance) is adjusted by input offset value.
The input value of offset is cleared when you save
the surveying point and step forward
to the next surveying point.