3.4.1
Programming the Control Panel for Network
Communication
Using RPS (RAM IV)
1. Using RPS, receive the control panel's
programming. For more information, refer to
Section
4.3.1 Receiving Control Panel Programming
Using RPS
on page 124.
2. Using RPS, go into Gv2MAIN→Panel Wide
Parameters→Routing.
Set the Primary on Route Group 1 prompt to 1.
3.
4. Using RPS, go into GV2MAIN→Panel Wide
Parameters→Enhanced Routing.
5. Set the Route Group 1 Primary SDI prompt to
Yes.
6. Exit from GV2MAIN→Panel Wide Parameters
and select GV2AUX.
7. Click the small plus symbol and select Enhanced
Communications.
Bosch Security Systems, Inc. | 11/05 | F01U011024B
D9412GV2/D7412GV2 | Troubleshooting Guide | 3.0 Troubleshooting
8. Set the Enable Enhanced Communication?
prompt to Yes and enter the IP address of the
D6600 Receiver for Path 1 IP Address.
9. Select the Path 1 Poll Rate parameter. (For UL
requirements, refer to the DX4020 Installation Guide
[P/N: 49522]).
10. Using RPS, select D9412V2 Program Record
Sheet→GV2AUX→Misc.
11. Under the Misc prompt, select Enable Anti
Replay and select Yes for the value.
12. Send the programming data to the control panel.
For more information, refer to Section
Programming Changes to the Control Panel Using RPS
on page 124.
13. Reboot the control panel to synchronize the
numeric keys.