D9412GV2/D7412GV2 | Troubleshooting Guide | 4.0
D9133
Table 66: D9133 Specifications
Operating Voltage
Current Draw
Dimensions (Enclosure)
D9133DC
Table 67: D9133DC Specifications
Dimensions (Enclosure)
H x W x D
Current Draw
DX4010i
Table 68:
DX4010i Specifications
Operating Voltage
12 VDC
Current Draw
50 mA nominal, 55 mA with
diagnostic LEDs enabled
Communication
Programmable through the control
Configuration
panel. Refer to the appropriate
control panel programming
instructions.
Operating
0°C to +50°C (+32°F to +122°F)
Temperature
Relative Humidity
5 to 85% @ +30°C (+86°F) non-
condensing
Control Panel
Detection Systems Option Bus
Compatibility
DS7240, DS7220 and DS7400Xi;
Bosch Security Systems D6412,
D4412 or Bosch Security Systems
SDI Bus D9412GV2, D7412GV2,
D7212GV2, D9412G, D7412G,
D7212G, D9412, D9124, D9112,
D7412 and D7212.
132
Appendix
8.5 V to 14 VDC
39 mA (min), 45 mA (max)
14 cm x 8.3 cm x 4.5 cm (5.5 in. x 3.25 in. x 1.75 in.)
14 cm x 8.3 cm x 4.5 cm (5.5 in. x 3.25 in. x 1.75 in.)
50 mA (55 mA with diagnostic LEDs enabled)
DX4020
Table 69:
DX4020 Specifications
Dimensions
7.6 cm x 12.7 cm (3 in. x 5 in.)
Current Draw
84 mA maximum, 80 mA nominal
10 Base-T
110 mA maximum, 100 mA nominal
100 Base-T
Operation
12 VDC Nominal
Voltage
Connectors
Control
Panel
LAN/WAN
Ethernet
Category 3 or better unshielded twisted pair
Cable
Max Length
Interface
IEEE 802.3
Compatibility
Bosch Control Panels
- Version 6.3 or later
Default IP
0.0.0.0 (DHCP mode)
Address
Bosch Security Systems, Inc. | 11/05 | F01U011024B