Bosch D9412GV2 Troubleshooting Manual page 114

Hide thumbs Also See for D9412GV2:
Table of Contents

Advertisement

D9412GV2/D7412GV2 | Troubleshooting Guide | 4.0
D8125INV Wireless Interface Module
Figure 65: D8125INV Wireless Interface Module
Description: The D8125INV is an interface module
that allows connecting an Inovonics FA400 Receiver
and compatible transmitters.
Installation Location: Within 1.52 m (5 ft) of the
control panel. Can be in the control panel's enclosure
or in a nearby enclosure.
Control Panel Connection:
Zonex 1, Terminals 27 and 28.
Zonex 2, Terminals 25 and 26.
D8128C and D8128D OctoPOPIT Module
Figure 66: D8128C and D8128D OctoPOPIT
Module
Description: The D8128C and D8128D OctoPOPIT
Modules combine the functions of the D8125 POPEX
module and the D8127/D9127 POPIT modules to
provide eight off-board points in a single module. You
can wire both the D8128C/D OctoPOPIT and D8125
POPEX modules in parallel to the Zonex bus terminals
on the same control panel.
Installation Location: Up to 61 m (200 ft) away from
panel, in the control panel enclosure, or in a separate
enclosure.
Control Panel Connection:
Zonex 1, Terminals 27 and 28.
Zonex 2, Terminals 25 and 26.
114
Appendix
D9210B Access Control Interface Module
Figure 67: D9210B Access Control Interface
Module
Description: The D9210B is a fully-supervised,
addressable serial device interface (SDI) bus device
that allows the D9412GV2 (eight doors) and
D7412GV2 (two doors) control panels to provide
access control functions. Each D9210B can store up to
986 user tokens (300 tokens for D7412GV2), each with
a different access level for each door. Authority for
access is controlled by the level of the user, the time of
day, the state of the door, and the armed state of the
area to which the D9210B is assigned.
Installation Location: Up to 457 m (1500 ft) from
control panel, inside the control panel's enclosure, or
in its own enclosure.
Control Panel Connection: SDI bus, Terminals 30
and 31.
4.1.2
Setting Up the Control Panel
You must have a panel-wide keypad when performing
the procedure described in Section
Points Associated with Each Point Expansion Technology
page 115.
Use a keypad close to the control panel
when performing the procedure described
in Section
4.1.3 Identifying the Points
Associated with Each Point Expansion
Technology
1. To determine if your keypad is panel wide, or to
make it panel wide:
a.
Using RPS or your D5200 Programmer, select
GV2MAIN → Command Centers →
Command Center Assignments.
Bosch Security Systems, Inc. | 11/05 | F01U011024B
4.1.3 Identifying the
on page 115.