I
Probing
General Purpose Probing System Description
Probe Cable
The probe cable contains 18 signal lines, 17 chassis ground lines and two
power lines for preprocessor use. The cables are woven together into a flat
ribbon that is 4.5 feet long. The probe cable connects the logic analyzer to
the pods, termination adapter, HP 10269C General-Purpose Probe Interface,
or preprocessor. Each cable is capable of carrying 0.33 amps for
preprocessor power.
_C_A_U_T_l_O_N____ DO NOT exceed this 0.33 amps per cable or the cable will be damaged.
Preprocessor power is protected by a current limiting circuit.
If
the current
limiting circuit is activated, the fault condition must be removed.
W_A_R_N_l_N_G____ After the fault condition
is
removed, the circuit will reset
in
one minute.
Minimum Signal Amplitude
Any signal line you intend to probe with the logic analyzer probes must
supply a minimum voltage swing of 500 m V to the probe tip.
If
you measure
signal lines with a voltage swing of less than 500 mV, you may not obtain a
reliable measurement.
Maximum Probe Input Voltage
The maximum input voltage of each logic analyzer probe is ±40 volts peak.
Pod Thresholds
Logic analyzer pods have two preset thresholds and a user-definable pod
threshold. The two preset thresholds are ECL ( - 1.3 V) and TTL (
+
1.5 V).
The user-definable threshold can be set anywhere between - 6.0 volts
and +6.0 volts in 0.05 volt increments.
All pod thresholds are set independently.