Turn battery load tester OFF before disconnecting tester
cables to battery terminals. Disconnecting tester cables
with load tester ON can cause a spark and battery explo-
sion, which could result in death or serious injury. (00253a)
Connect positive (+) battery cable first. If positive (+) cable
should contact ground with negative (-) cable connected,
the resulting sparks can cause a battery explosion, which
could result in death or serious injury. (00068a)
Do not over-tighten bolts on battery terminals. Use
recommended torque values. Over-tightening battery ter-
minal bolts could result in damage to battery terminals.
(00216a)
6.
Install the battery on the motorcycle.
1-34 2008 Buell XB Diagnostics: Starting / Charging
ed01461
1. Load Tester
2. Induction Pick-Up
3. Battery
Figure 1-27. Load Test Battery
Table 1-12. Battery Load Test
COLD CRANKING
100%
AMPERAGE (CCA)
All Buell models
1
2
3
50%
200
100