Solenoid Hold-In Test; Solenoid Return Test - Buell 2008 XB SERIES Electrical Diagnostics Manual

Table of Contents

Advertisement

ed01527
1
1. Motor terminal
2. Battery
3. Relay terminal
Figure 1-13. Test 1: Pull-in Test

SOLENOID HOLD-IN TEST

1.
See
Figure
1-14. With test leads still connected in the
manner specified in the previous
ON BENCH, Solenoid Hold-In
motor terminal/battery negative test lead (B) at negative
battery post only; reconnect loose end of this test lead to
positive battery post instead.
2.
Observe starter shaft.
a.
If starter shaft remains extended, solenoid is working
properly.
b.
If starter shaft retracts, replace the solenoid.
2
3
1.8 TESTING STARTER
Test, disconnect solenoid
ed01528
1
1. Motor terminal
2. Battery
3. Relay terminal
Figure 1-14. Test 2: Hold-in Test

SOLENOID RETURN TEST

1.
See
Figure
1-15. With test leads still connected in the
manner specified at the end of the previous
STARTER ON BENCH, Solenoid Hold-In
solenoid relay terminal/ positive battery post test lead (C)
at either end.
2.
Observe starter pinion.
a.
If starter shaft retracts, solenoid is working properly.
b.
If starter shaft does not retract, replace the solenoid.
2008 Buell XB Diagnostics: Starting / Charging 1-23
2
3
1.8 TESTING
Test, disconnect