Bank Angle Sensor: DTC P1151 (44); DTC P1152 (44) (Part 1 of 2)
Disconnect Bank Angle Sensor
connector [134]. Measure voltage on
1
[134B] between terminal "5" (LGN/GY)
terminal "4" (R/W) and terminal
2
Are ferrous metals located within
0.25 in. (6.4 mm) of sides, face or
Clear DTCs and confirm proper operation with no
check engine lamp. Codes can be cleared using
DIGITAL TECHNICIAN (Part No. HD-44750).
YES
and terminal "6" (BK/W).
What is the voltage?
4.75-5.25 volts
Measure voltage between
"6" (BK/W).
Is voltage 4-6 volts?
YES
Is Bank
Angle Sensor
properly installed?
YES
top of Bank Angle Sensor?
YES
Return to original
configuration.
NOTE:
Is Bank Angle
Sensor connected?
Connect Bank Angle Sensor and
clear Codes. Cycle Ignition
Switch. Recheck for codes.
11-13 volts
Repair short to
voltage on
(LGN/GY) wire.
Go to Bank Angle Sensor
Test, DTC P1151 (44);
P1152 (44) (Part 2 of 2).
NO
Repair open in
(R/W) wire between connector
[134B] terminal "4" and
connector [11B] terminal "25".
Install properly. See BANK
ANGLE SENSOR in the appropriate
Buell Service Manual.
Replace Bank Angle Sensor. See BANK
ANGLE SENSOR in the appropriate
Buell Service Manual.
2008 Buell XB Diagnostics: Engine Management 2-117
NO
0.0 volt
STOP
NO
NO