Bank Angle Sensor: DTC P1151 (44); DTC P1152 (44) (Part 2 of 2)
2-118 2008 Buell XB Diagnostics: Engine Management
Continued from Bank Angle Sensor Test, DTC P1151
(44); P1152 (44) (Part 1 of 2).
Disconnect connectors [10] (Black) and [11] (Gray) from
2
ECM and plug into Breakout Box (B-48115). Check
continuity between connector [134] terminal "5" (LGN/GY)
and connector [11] (Gray) terminal "17".
Is continuity present?
YES
Check continuity between connector
[134B] terminal "6" and connector
[11B] (Gray) terminal "19" (GY).
Is continuity present?
YES
Check (LGN/GY) circuit continuity to
ground for connector [134B] terminal "5"
and connector [11B] (Gray) terminal "17".
Is continuity present?
YES
Repair short to ground
on (LGN/GY) wire.
NOTES:
Clear DTCs and confirm proper operation with no check
engine lamp. Codes can be cleared using DIGITAL
TECHNICIAN (Part No. HD-44750).
After replacing ECM or TPS, TPS zero set procedure
must be performed. Refer to THROTTLE POSITION
SENSOR in the appropriate BUELL SERVICE MANUAL.
NO
Repair open in
(LGN/GY) wire.
NO
Repair open on (BK/
W) wire.
NO
Replace ECM.