CCD unit
・Mount the CCD unit (#B3051) by following the direction for positioning, and fix it with three screws (#631).
#631×3
Direction for positioning
#B3051
Loft PCB / TOGO PCB
・Attach the loft PCB partially with the adhesive double-coated tape.
・Solder the eight wires.
・Connect the two FPCs to each connector.
・By watching the wires and FPCs, mount the TOGO-PCB (#B2001).
Red:Backup battery
Pull the blue wire from here.
(Back) TOGO PCB unit
(#B2001)
- A ・
Caution:
Some bodies have already washer(s) attached on
the mounting surface of CCD unit.
Yellow:DC/DC
(Back)
Adhesive double-coated tape
Gray:Buzzer unit
Gray:Buzzer unit
-
logo_Q0650_forGraphic
071004_Gdesign_ito
INC
VBA21001-R.3753.A
Red:DC/DC
Blue:DC/DC
Purple:DC/DC
Green:DC/DC
Loft PCB
#1031