Inspection and Adjustment of Body back

"0" positioning of the dial gauge
Surface plate
① Put the tool (J18001-1) on the surface plate, and set the dial gauge to "0".
② Turn the index ring in the direction of the arrow from the above "0", and set the scale to "8
"0"-position of D60.)
③ Measure the body back, based on "0" reference position of the index ring.
・ Measure three parts from the bayonet face to the CCD-
PCB attaching face.
 
Standard:48.59±0.015mm/ Parallelism: 0.015mm or less
・In case it is out of standard, make adjustment
by loosening screws that attach the front and rear bodies,
or by putting the washer(s) on the contact surface
between the front body and rear body.
Note: For some bodies, washer(s) or tracing-film sheet are already put on the attaching face of the CCD-bracket.
There are three cases as follows.
1. Purpose:To adjust the height of the camera body
There are indications by color marker on the CCD-PCB attaching face of the camera body side .
{Blue =0.02mm (#87), Red = 0.01mm (#88), Green = 0.06mm (#89)}
* By adding the measured value to the thickness of washers, check if it is within the standard (48.59±0.015mm).
2. Purpose:To adjust the height of the CCD bracket
   There are indications by marker on the CCD-bracket attaching face
One marking = Put three washers [#88 (0.02mm)] at three places
Two markings = Put three washers [#87 (0.1mm)] at three places
* When the CCD PCB is replaced, remove the washers.
3.Any marking(s) of the three in the right "Fig. ① " =
Put the tracing-film sheet (#84) in the marked place(s).
* When the CCD PCB is replaced, remove the tracing-film sheet.
- A  ・
-
logo_Q0650_forGraphic
071004_Gdesign_ito
INC
VBA21001-R.3753.A
0" position of D60
. (This is
"
Measuring point
Marking
Fig. ①