When the AE-CCD positioning is adjusted, solder the only four wires that connected from the
top cover to SB-PCB. Then, make a temporary assembly without mounting the rubber eye-
cap (#B271), and assemble up to Page A27.
Top cover
・Mount the rubber eyecap (#B271).
・Watching the wires and FPCs, mount the top cover.
・Tighten two screws (#5737) and two screws (#635).
DC/DC PCB unit
・Solder the wire (connected from Top cover).
SB PCB
・Solder the four wires
(connected from Top
cover).
#B271
#487×2
#486×2
#635×2
Black: Top cover
Orange:
Top cover
White: Top cover
Gray: Top cover
Black: Top cover
- A  ・
logo_Q0650_forGraphic
071004_Gdesign_ito
#5737×2
-
INC
VBA21001-R.3753.A