In the factory settings, the installation mode is disabled.
1. To enable the function, select a time from the drop-down list during which the
installation mode is enabled (15/30/60/120 minutes).
2. Click the "Save" button.The SINAUT MD741-1 restarts and the entries
described below appear.
3. You can stop the enabled function prematurely by selecting the "No" option.
Status of the current wireless cell
In this area of the page you will find information that relates to the mobile wireless
cell in which the SINAUT MD741-1 is currently logged in.
Status of the neighboring wireless cells
In this area of the page, you will find information that relates to the neighboring,
available mobile wireless cells.
Information about the wireless cell
Signal strength
The bar display indicates the strength of the GSM signal.
The numbers above the bar display indicate the CSQ value of the signal.
The dBm value is shown in brackets after the CSQ value.
ID of the wireless cell
ID for the wireless cell in the mobile wireless network
LAC (Location Area Code)
ID for the current location of the SINAUT MD741-1 within the mobile wireless
network
ARFCN (Absolute Radio Frequency Channel Number)
Based on the ARFCN, the uplink and downlink frequencies can be calculated.
BSIC (Base Station Identity Code)
This ID is used to be able to distinguish neighboring channels when the frequency
bands overlap