Siemens SINAUT MD741-1 System Manual page 129

Egprs/gprs-router
Hide thumbs Also See for SINAUT MD741-1:
Table of Contents

Advertisement

Max. transmitting
power (acc. to
output 99, V5)
Antenna
connection
Temperature
Ambient
conditions
range
Air humidity
Housing
Design
Material
Protection class
Dimensions
Weight
DE
CE
GSM/EGPRS
module
Environment
Input voltage
Power supply
Input Current
Power input
Current
consumption
Input current
characteristic
SINAUT MD741-1
C79000-G8976-C236-05
Class 4 (+33dBm ±2dB) for EGSM850
Class 4 (+33dBm ±2dB) for EGSM900
Class 1 (+30dBm ±2dB) for GSM1800
Class 1 (+30dBm ±2dB) for GSM1900
Class E2 (+27dBm ± 3dB) for GSM 850 8-PSK
Class E2 (+27dBm ± 3dB) for GSM 900 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1800 8-PSK
Class E2 (+26dBm +3 /-4dB) for GSM 1900 8-PSK
Nominal impedance: 50 ohms, jack: SMA
Operation: -20 °C to +60 °C
Storage:
-40 °C to +70 °C
0-95 %, non-condensing
Top-hat rail housing
Plastic
IP20
114 mm x 45 mm x 99 mm
approx. 280g
Yes
Conforms to GCF, PTCRB
The device complies with the European Directives
RoHS and WEEE.
12 - 30 V DC (24 V DC nominal)
510 – 230 mA DC
4.4 W typical at 12 V
4.0 W typical at 24 V
4.5 W typical at 30 V
See table below.
[mA]
1400
1200
1000
800
600
400
200
10
20
30
40
4,62ms burst repeat rate
[mA]
800
600
400
200
10
20
30
40
4,62ms burst repeat rate
11 Technical Data
I
at 12V
Burst
50
60
70
80
90
I
at 24V
Burst
50
60
70
80
90
[ms]
100
[ms]
100