Restart of the VPN client with DPD
If the SINAUT MD741-1 does not receive any reply to its DPD queries from the
remote station, the IPsec connection is considered to be interrupted after a number
of permitted unsuccessful attempts. You can specify whether or not the
SINAUT MD741-1 is rebooted in such a situation.
Remember that if you reboot, not only the failed connection but all existing VPN
connections will be interrupted.
Select one of the two options:
Yes:
No:
Factory settings
The factory settings for the SINAUT MD741-1 are as follows:
Keepalive interval for NAT-T (seconds)
Phase 1 timeout (seconds)
Phase 2 timeout (seconds)
Maximum number of connection establishment attempts up
to restarting the VPN client
Maximum number of connection establishment attempts after
restarting the VPN client until the next device restart
DynDNS tracking
Interval for DynDNS tracking (minutes)
Restart of the VPN client with DPD
SINAUT MD741-1
C79000-G8976-C236-05
The device is restarted as soon as DPD is detected.
The device is not restarted following DPD.
7 VPN connection
60
15
10
5
2
Yes
5
No