7 VPN connection
If no remote station answers the ping packet the transmission of the ping packet
will be repeated several times after a delay which can be configured. If all
repetitions end without success, the VPN client in the SINAUT MD741-1 are will be
restarted. This causes a reconnection of all existing VPN connections.
Notice
Sending ping packets (ICMPs) increases the amount of data sent and received via
EGPRS or GPRS. This can lead to increased costs.
Enable VPN supervision
Yes: VPN supervision on.
No: VPN supervision off
Interval for connection check (minutes)
This parameter determines the time interval to send ping packets through the
supervised VPN connection (VPN tunnel).
The value shall be given in minutes.
Waiting time before repetition (minutes)
This parameter determines the delay a ping packet is repeated after a failed ping
check (ping packet not answered).
The value shall be given in minutes.
Number of unsuccessful connection checks up to restarting the VPN client
This parameter determines the number of allowed failed ping transmission retries
before the VPN client inside the SINAUT MD741-1 are will be restarted.
Destination hosts
Tunnel name
Determine, which VPN connection (VPN tunnel) shall be supervised. Add a VPN
connection by clicking the New button, delete a VPN connection by clicking the
Delete button.
Host IP address
Enter the IP address of the remote station (target host) here.