Siemens SINAUT MD741-1 System Manual page 34

Egprs/gprs-router
Hide thumbs Also See for SINAUT MD741-1:
Table of Contents

Advertisement

3 Configuration
CSD Dial-In
Shows whether remote CSD service calls are allowed.
: Access is allowed.
: Access is not allowed.
Traffic volume supervision
Shows whether the volume monitoring is on or off.
: The function is enabled.
: The function is disabled.
ID of the current wireless cell
With the identification number, this entry shows the wireless cell in which the
device is logged in (Cell ID).
Number of WAN connection attempts (24 h)
This counter shows how often the SINAUT MD741-1 attempted to establish a
connection to the mobile wireless network in the last 24 hours.
Bytes sent and bytes received on this connection
These entries show the number of bytes that have been sent or received during the
current connection to the mobile wireless network.
The counters are reset when a new connection is established.
Note
These figures serve only as a general indication of the data volume, and can differ
significantly from the mobile wireless provider's accounting
Bytes sent since loading the factory settings
These entries show the number of bytes that have been sent or received via the
mobile wireless network since the last restart of since the last time the factory
settings were loaded.
The counters are reset when the factory settings are loaded.