Appendix F Power Supply Specification
1. Input Power Specification
Specification
Input Voltage Range
Frequency Range
Power Consumption
Regulation Efficiency
2. Output Power Requirement
The power supply can provide DC output as below:
NO.
Voltage
+5 V
1
2
+2.5 V
3
+12 V
3. Lamp Power specifications
Specification
Applicable Lamp
Starting pulse from Ignitor
The unit shall meet all the operating requirements with the range 100
~ 240 VAC
The unit shall meet all the operating requirements with an input
frequency range 50 Hz ~ 60 Hz
Normal operation: 285 W (Max)
standby mode: < 5W
80 % (typical) measuring at 115Vac and full load
Regulation
Load Current Range
±5 %
±5 %
±10 %
Description
200W, AC operation
Pulse voltage 7KV max.
Description
0.06A ~ 2 A
0.3 A ~ 2 A
0.04 A ~ 1A
41
Ripple & Noise
100 mV
100 mV
300 mV