Test Conditions; Test Equipments; Visual Inspection Criteria; Inspection Zone Definition And Inspection Distance - BenQ MP611 Product Service Manual

Hide thumbs Also See for MP611:
Table of Contents

Advertisement

Manual, CD and the like, and being inspected as a part of the complete product, must
be included in the evaluation.
5) The evaluation must be within the limits of the product specification and, for not
specified characteristics, refer to the sample machine or the judgment of BENQ
QA Engineer. But any kind of proposals or judgments must be reasonable and
acceptable by both sides.
6) Faults must be able to be repeatedly demonstrated.

5.3.9. TEST CONDITIONS

Unless other prescription, the test conditions are as followings:
Nominal voltage: refer to operation manual
Environmental illumination:
Variable from 300 to 700 Lux (For appearance inspection)
Variable from 0 to 7 Lux (For functional inspection)
Temperature: 25±5℃
Warm up time: at least more than 10 minutes
Visual inspection shall be done with the distance from eyes to the sample 50 cm.
Display mode: refer to operation manual

5.3.10. TEST EQUIPMENTS

Dark room
PC
Pattern Generator: Chroma 2327
Minolta color analyzer (CL-100)
BS tuner (Sharp TU-HD1/ Panasonic TU-BHD300, or equivalent)
DVD player
Power supply (100~240 VAC) with consumption meter
Measuring tape
5.3.11. PART Ⅰ VISUAL INSPECTION CRITERIA

5.3.11.1. Inspection zone definition and inspection distance

A-side:
Up case
Front cover - Front cover surface
- Up case surfaces except right / left / behind side's surface.
47