Expression Of Defectives; Inspection Standard - BenQ MP611 Product Service Manual

Hide thumbs Also See for MP611:
Table of Contents

Advertisement

Note: If BenQ defect undefined failure, and it judged that is reduce the
merchandisebility, BenQ
communication and decide how to solve.

5.3.6. EXPRESSION OF DEFECTIVES

Percent of defects = ------------------------------------------ X 100%

5.3.7. INSPECTION STANDARD

Unless otherwise specified, the inspection standard will be defined by MIL-STD-105E,
NORMAL INSPECTION LEVEL Ⅱ, SINGLE SAMPLING PLAN. Level Ⅱ is in use all the
time, inspection levels are normal, reduce and tighten.
5.3.7.1 Acceptance Quality Level
5.3.7.1.1. Critical Defect:
When a critical defect is found, this must be reported immediately upon
detection, the lot or batch shall be rejected and further shipments shall be held up
pending instructions from the responsible person in relevant department.
5.3.7.1.2 under normal sampling
Critical
Major
Minor
5.3.7.1.3 under special sampling
Critical
Major
Minor
5.3.8. GENERAL RULES
1) The inspection must be carried out by trained inspectors who have good knowledge
about the product.
2) The inspection must be based upon the documents concerning the completely
assembled and packed product.
3) When more defects appear with the same unit only the most serious defect has to be
taken into account.
4) Defects found in accessory packed with the product such as Cable, Connector,
CM Inform this defect. After that parties make
Number of defects
Number of products inspected
Defective : 0% AQL
Defective : 0.65% AQL
Defective : 2.5% AQL
Defective : 0% AQL
Defective : 1.0% AQL
Defective : 4.0% AQL