B2.3 Regulatory
EMC
ESD
Surge
Safety
B3. Failure Criteria
The product is expected to perform to its full potential without loss of function, performance,
critical parametric changes, and other undesirable anomalies, over the applied boundaries of this
specification. The following product failure is not allowed within the boundaries defined in this
specification:
1. Failure including permanent damage, critical paramedics changes (optical performance defined in
Appendix A), and latent defects.
2. Failure requiring operator intervention.
3. Failure violating external laws, regulatory agency standards, and government directives.
4. Failure resulting in a safety, potential safety, issue.
30 @0~12,200m above sea level
Turn On @ 0
and 40 , AC90~264V, 47~63Hz
Test condition:
FCC part 15J class B, EN55022 class B, under 3 dBuv
1. Air discharge to set surface: 15KV
2. Contact discharge to set surface and metal: 8KV
3. Contact discharge to Vert./Horiztl coupling plane: 8KV
4. Contact discharge to D-sub/S-video input pins: 4KV
1KV line to line, 2KV line to ground on input power lines.
Please refer to UL1950 for details