Adjustment / Alignment Procedure
1. DMD Bias Voltage Alignment
Equipment:
-None
Procedure:
1
Watch DMD chip Label (Example: 9477000 0234B)
2
Switch the DIP switch on DMD board according to the red character on the DMD chip
2. Color Wheel Delay Alignment
Equipment: -Battery Biased Silicon PIN Detector -Oscilloscope (Vertical scale set to 10mV) -Probe
Procedure:
1
Probe impedance matches 50 ohm