Led Messages Definition - BenQ MP611 Product Service Manual

Hide thumbs Also See for MP611:
Table of Contents

Advertisement

Chapter 4 LED Messages Definition
Status
Power Temp Lamp
O
-
-
Stand-by
G
-
-
Powering up
G
-
-
Normal operation
O
-
-
Normal power-down cooling
O
-
-
First Lamp-Lit error cooling
Lamp Error Messages
O
R
-
Second Lamp-Lit error
R
-
-
Lamp error in normal operation
Thermal Error Messages
R
-
-
Fan 1 error (
R
R
-
Fan 2 error (
R
G
-
Fan 3 error (
R
O
Fan 4 error (
Thermal Sensor 1 open error (the remote diode has an open-circuit
R
R
R
condition.)
Thermal Sensor 2 open error (the remote diode has an open-circuit
R
R
G
condition.)
Thermal Sensor 3 open error (the remote diode has an open-circuit
R
R
O
condition.)
Thermal Sensor 1 short error (the remote diode has an short-circuit
G
R
R
condition.)
Thermal Sensor 2 short error (the remote diode has an short-circuit
G
R
G
condition.)
Thermal Sensor 3 short error (the remote diode has an short-circuit
G
R
O
condition.)
O
R
R
Temperature 1 error (over limited temperature)
O
R
G
Temperature 2 error (over limited temperature)
O
R
O
Temperature 3 error (over limited temperature)
G
R
-
Fan IC #1 I2C Connection error
G
G
-
Fan IC #2 I2C Connection error
the actual fan speed is ±20% outside the desired speed.)
the actual fan speed is ±20% outside the desired speed.)
the actual fan speed is ±20% outside the desired speed.)
the actual fan speed is ±20% outside the desired speed.)
129
Note
Lamp Fan
Ballast Fan
Blower Fan
DMD sensor
DMD sensor
DMD sensor
GMT 793

Hide quick links:

Advertisement

Table of Contents
loading